Loading...
HomeMy WebLinkAboutOrdinances_1315_CCv0001.pdf ORDINANCE Nd...1:3155 cavating:.;: filling, or any combination adjacent::properties as before the ex- ANT ORDINANCE OF THE CITY OF thereof. cavation or fall, or so that the sur REDLANDS ESTABLISHING THE C. City --- The City- of Redlands, face drainage of the lot is convert- REGULATION onve t-REGULATION OF EXCAVATION California, trated or collected and discharged: AND PILLS OF ANY LOT, SUB D. Building and safety Suporin- at an accelerated rate, or in such a (DIVISION, €1'R P A R C E L OF tendent .-- The officer charged with way that it will probably result: i GROUND. AND REPFALIIVG CSR.- the administration and enforcement darnagc, err in a -,vay- that creates n FSINA C'E NOS, 1235, 1262. ANP of this Code, or his regularly author- hazard to the public health, safety 1233. ized deputy. or Property or to such an extent TA=E CITY COU CIL O'F"1RY CITY R. Developer — Any Person, firm ill At the excavation or filling will OF RES?1„r3NDS DOES rORDAIN AS or corporation developing or con- require or be accompanied by the FOLLOWS: to,plating the development of land hauling of earth or other materials SrCrIO 1.00 -,ciibin tike City* for any use whatso- over any public street in a vehicle INTENT AND PURPOSE even with a gross weight of vehicle and The purpose of this Ordinance is F. Engineer -- A Civil Engineer load in excess of that permitted by to safeguard life, health, limb, prop- registered in the State of California law or ordinance of the City., erty and public welfare by regular-... and experienced in the field of land SECTION 7,04 ing and controlling the design,can- development, grading arid drainage. PLANS AND SPECIFICATIONS ctractiin, quality of materials, Inca G. Excavation: Excavation shall eat With eachapplication for :a tion of all buildings and structures cancan any act by which earth, sand, permit tura sets of plans and speci erected or to lie ereeted, and certain gravel, rods or away other similar ficaations shall he ohm tied. The grading sad pawing within the City materia: is removed, Pushed, pulled Building. and Safety Superintendent: c,f Redlands. The provisions of: this: or transported to a. place other than may require plans and specifications chapter are staPPlemontarY. cknci im the place from which it was re- to be Prepared and signed by a Civil addition,to the subdivision ordinance. moved car any material that has been Engineer licensed. by the State of.. add do zoning ordinance of the.:nee loosened. or disturbed from its natu- California. An approved set of plans and the z lie read and construed the to sot state where it was deposited by shall be accessible on the job site:. connection with, and as.'an ntegrated.. evolution of geological processes.. at all tunes during construction. e. part, of the zoning ordinance. and:: H. Fills -- Fill shall mean any:act plans And specifications shall define:: subdivision ordinance and the ;pat- by which earth., sand, gravel, rock the following: terms of land development control: or any :rather similar material is do- 1, Property lines of the Property; established thereby. posited, Placed,. pushed, pulled. or on which the Work is to be per- In adopting, this Ordinance,. the. :transported to a:place other than the formed City Council declares the regulations place from Which it wait excavated, 2. Dimensions and locations of all and standards established herein to or any iataterial that has been buildings or structures on the prop Ire the reasonable regulations neces- loosened or disturbed from its na:tu- erty *where the work is to be Per- xary to protect the health, safety ral state, where r it was deposited by formed and the location of any and general ;°el#are: tai Promtate a evolution of geological processes. building or structure on land of ad- superior community empromotena I. Final Grading --- Final grading javent properties which are within and insofar as it is economically shall mean that grading operations twenty f20, feet of the property on feasible, to ensure the inaxitiaum have been completed and.. are as which the work is to be performed, possible preservation of the natural: shown on the approved grading plane :3. Legal description of the prop- scenic character of major portions and shall include all paving, curbs, erts, on which the work is to be per cif the. City; by establishing mini- drain, sprinkler systems and land- formed. -num standards and requirements ro- coping, 4, Elev'at'ions, dimensions, location,- lating to land grading,. paving and: J. Grading —� The rearranging:or extent and the slopes of all work procedures by. which these standards changing of the surface of the soil proposed to be done, shown on a and requirements may: be enforced from its natural condition by arti- contour map. The.contour map shall:: It is intended that this chapter be h-cial *cleans, show, the existing contours of the administered with its,. foregoing Put- IC. Per Cent: of CompactionPer land andthe finished grade of the poses in mind arid ww'itha view to: seat of cornpaction shall mean the hand after completion of.the work.,. saw Ensuring that future develop per cent of maximum dry density the relation of the finished grade to corm of lands; particularly in the: ns determined by ASTM ID1557-58T, the streets and alloy's, driveway ails« i lly <,re.,s of the City, Decors in the:: Field dry deaasity shall be.determined proacheq:. and easements for drain manner least compatible with stn• by ASTM LD1556-58T. age on involved properties. rounding areas so as to have: the: L. Perm ittee — 'rhe p e r son: to 5. Detailed Plans of all vralls. trast adverse effect upon other Per- whom a grading:permit is issued un- curbs. drains, berms. driveway ap -.oris. or lands.;: or tailor the general der the provision of this ordinance, proaches., or other Protective devices.. public: his agents, employers, contractors, constructed in connectionwith the. tba Ensuring that loll viii not be imeorttractors and Persons perform- proposed work together with a snap -trmped and reproved from lands ing work in his:behalf, showing.the drainage area and esti - hi CIA -,note scenic parts; of the City, M. Rough Grading Rough grad- mated cubic feet per second runoff. leaving. the same barren, unsightly,:. ing shall mean. that portion of the of the area served by any draim unproductive, and subject to erasion grading operation that is approxi 6. Any additional plans Or draw and the hazards of Eta!>r„idenGe; in- mate in elevation and parallel to ings required by the Building and stability and faulty drainage, the ilmssh contours,urs, and shall include Safety Superintendent. ,c, Encouraging the 'planning, de- Protection of all building areas from rb5 sail Engineering Report. The sign and development of building surface waters and shall include Building and Safety Superintendent sites in such fashion as to provide adequate drainage facilities to pre- may require A soil engineering re- t maximum in safety and human: vent erosion and.to protect the prop- port based on the proposed grading. ommyruent, while adapting develop- erty and adjacent property from slur- plan. Such report: shall include data.. :sent to and taking advantage of the face ivater damage. Rough grading regarding the nature, distribution, hest use of the natural terrain; shall be parallel: to the..:finish grade and strength of existing sells, ton +di Encouraging and directing spe- and located a maximum of four W cln%ans and recommendations for tial attention toffs=ard retaining,:..in». inches from the finish grade indi- grading procedures and design cri-. antic as practical, the natural plant- cared teria for. corrective measures. R.ec in and a inaxirnum number of exist- Site —Site shall mean any lot, oro menta#ions included in the re axg trees. parcel of land, series of lots, or Port and approved by the Building SECTION l.at parcels of land joined together un- and Safety Superintendent shall be SCOPE der One ownership where gradin* is incorporated in the approval grad No person, firm or corporation: to be performed or is being Per- ing plan and specifications Prior to shall, do any grading err Paving not folioed. sstaing a permit. n compliance with this Code. If two t5. Seidl Engineer h S Civil Call- alEngl- SECTION 1.051. or more provisions of this Code and neer. registered in the State of Cab- atas Cather aplali,cakkle. Iain are in con- formic, with a specialty and experi-. PERMIT FEES: enced in the analysis of soils for : a s"et, that: ww==hich provides: the great- A fee for each permit shalt 1 PStructure restrictions in the opinion of the construction, _ That which Is paid to life office of the City Treas- Building . st t Ci Asad Safety Superintendent. ux•er as set forth oat Tables 1-A and built of constructed, an edifice r ',trall grew aih 't`ahEes 1--8, plus. a Permit Fee of building work of ici kind, cis° Any pkeee ST:C:11CaN 1.012 $2.00. DEFINITIONS of work artaficzsj joibuined og or Com- tat Plan Checking Fees. The plan For the purposeof this Ordinance, posed of Pal°ks pained tragether in some definite manner. checking fee shall be erne-half ttf'- t.he following terms shall be definedSECTIC57 1 0� the permit fte As shown in Tables ass follows: I-A and 1-13, A, Building.•._ Ano structure built PERMITS RELfLtI£iEI7 TABLE I-A GRADING PERMIT for the support, shelter, or cnclo- A permit from- the Building. and FEES sure of person:;.. Animals,. chattels:,:: Safety Department is herebc=.. re- 0 to: 100 cubic yards„ ,30.00.... or Property of any kind. quired before the commencement of 101 to 1000 cubic yards, $10.,00 Ft, Building:..Pad -- A. relatively any phyvleal Wark of: grading any for the first 100 cubic yards, flat site which....is designed to be: oc-a lot or parcel of land, or for any plus $7.00 for each addition copied by any building, structure:: changes.:in the existing slope of the; al 100 cubic yards or fraction. or vehicle and: is prepared by..arti- surface of any lot so that it will:not: thereof: .... final means, installing grading, ex- take natural runoff of water from 1001 to 10,000 cubic yards, 5;11,00 for the first lot's cubic _yards, for approval anal file in the records other materials to alleviate the exist- pill,, $6,001 far each addition of the Building..and Safety Depart- ing hazard a mimmune charge of'.. al logo"cubic yards or frac- ment of the City of Redlands fearde, or a charge for .'55.�� vt'i3i be ma tion thereof. future reference and record. labor and materials will be ma.de:,:. 10.001, to 10o,c#uo cubit yarc#s, 9122,00 SECTION 1.07 whichever is greater, for Tile: first 10,Odri`3 cubic.: BOND REQUIREMENT SECTION 1.10 :yards, plus $27.rio for each FAITHFUL P E R F O 1 M It:'sl C E. EKCANIATIE;Ia+T GENERAL additional 10,000 cubic yarb; BOND: The perrrsUtee shall furnish tar leo grading or excavation :shall or fraction l hereof. a surely bond as provided under the be made with cut face steeper in °,t't3.litli:.cubic yards or more, $:3125.00 :proe ions of Sections 9249,1 and slope than two 6Z horizontal to one:. for the firs', 100,000 cubic g2491 of the Redlands Ordinance +:D vertical. .cards, plus$15.00 for each.ad_.. Code acid oil amendments, thereto. ,b, The Building.and Safety Super dstional 10,000 cubic yards or Sections 9244.1 and 9249,2 and all intendant may upon request permit: fraecion thereof, amendments thereto :are hereby slopes steeper than two ?2+ hori Ta1BLE 1-B PAVING PERMIT FEES adoia"ted and nuxle a part of this zontal to one =1b vertical. but not ,Applicable to each lot or Parcel of section as though fully 'let forth exceeding cine by horizontal to one ground', Saeresn, 11 vertical, provided the ovmer` 11,00 sq are £seer or less $;5ko SECTION 1.08 snail furnish a written report by a 1001 to atkCao square feet 7.oroo NOTIFICATIONS, i-NSPECTIONS Soil Engineer certifying that he has Vial to 2b,00u square feet 20,00 AND REPORTS investigated the situ and that. the 2p,001:to 100,000 square feet 30.04. i? The pe;rrnittee shall notify the proposed.:deviation will not endanger. 100,001: or more 40.00 Bulldsng and Safety Superintendent an,, property or create a, hazard.... €b` Where work for which a :per-:: as follows: 'ca The Building slid Safety Super- mit is required by this ordinance is 1, Whenever work on.:grading,:ex- intendant may require the slope to ,;tamed prior to obtaining said per cavation, fill or paving is readyIn be flatter than tufo 121 horizontal to nut, the fees. :above specified :shall: :conaet:enae, and prior to the starting:. one ,11 'vertical if it is determined he doubled, but the paytneant of suchof any swork. that the material in which the ex- double tee shall not relieve any Per- 2. [:,pan commenesmt if any, work eavation is to be made will he on- sons fronx fully complying with. the which has been: stopped for more stable at the proposed slope. ,equirentents of this ordinance in. than ices 00I days. sdi ho slope shall be constructed:. the execution of ilia work or from: 3, Whenever the existing ground over thirty-five o351 feet vertical ,airy other penalties prescribed here has been reworked and is ready to height unless the Building and Safe- in. receive tall. ts' Department is furnished evidence er The issuance or granting of a 4. When all rough grading has by a written report from a Soil En- peri-rut: or approval of pians and: been completed and the property gineer certify-=ing that such slope will 4pecifisations shall not be construed- corner stakes are in place and the be stable ,with a. safety factor of at t.a be a permit for. or an approval location of the st a vures have been least one and five-tenths il.Si, of, any violations of any of the pro staled=and finish, floor elevationin- ser All cost slopes in exc€ss. of tision3 of this ordinance, No permit: dteat€d. thirty-fine a35i feet vertical height: presuming to give authority to via-: 5. When all _work including in- shall have concrete leaved water late or cancet. the.provisions of.this: retaliation of all: drainage structures carrying Terraces at a rriaximxum.of ordinance shall:be valid.. and other protective ground devices t-wenty=-five t25l: :feet "vertical, inter.... Edi Every pe:r-nit issued under the have been completed. Soil engineer- gals, with :such.. terraces draining: provisions of this ordinance shall ex- ing reports shall be required by the into, a concrete paved gutter or pipe. a re by limitation and become null Building and Safety Superintendstit adequate to convey the water safely l prior to rough grading approval, to an approved disposal area. Drain ori void it the work authorized by abs Rough Grading Certificate age terraces are to be a minimum aid permit is riot Col^,�imenced with 1, Upon eompletmir of the rough of five ¢St feet in width.. in -ivty i6in days from the date of grading and before approval is given, ifro A twelve (12) inch high batch said per scat. 1 ermnts shalt be valid a Soil Fligmeer's report including or curb shall be placed at the top for a period of one va p ;;car, unless certifaeation of soil bearing capacity, of aft slopes roil the ground surface er ti x3e s extended at tile dis Su rc iarir of field and laboratory graded at a minimum of two per ct«.tion. of the Building; and Safety test::, location of teats and limits of: cent t2"s', awaylea , berm or curb. com pr:r;titendent.for good cause sbo nr �ci I'crrnz3t net Flegxs3red: A :fret. p,cted fill and location of noses This shape shall.. be continued until m it shall not be required by this or-< try, drainage devices will be shown any water draining from the top of ctsnance for any of the-:follow"zng: nn an "as built` plan to be Bob slope can be put into an approved. 1. An e:carration for S basenient nutted to the Building and Safety drainage device, footings for buildings, sornnoung Department. tg1 The top of all cut slopes he-- nools or structures authorized by a 2, There shall not be arty exca.va- tween adjoining lots shall be at the valid permit issued by, the City- of tion for building foundations, foot- property line. Redlands and covered by other Orth- ings or other excavations pertain Exception: Any portion of abutting- ivxnCesl coders Or laves. ing to the building construction lie property..that is: not a part of the.:. 3. .fta% odes Or la or fill not ex-- More the tough grading and construe.-. site under development. seeding fifty, f50) cubic yards of_me tion of drainage systems txecess�ry SECTION 1.11 protect adjoining property has teris3. alio not exceeding one ('I, foot b FILLGENERALS completed and approved. in. in depth on any lot or parcel of writing by the Sail Engineer and the fay No grading or fill shall be made ground. :Building and Safety Department.:.All a,'ith a :slope steeper than two :2i 3, Any approved reclamation or .alleys. and curbs shall be imbilled. horizontal ter one (U vertical. rubbich disposal site operated by any or grade stakes set to curb and alley- +iia The Building and .safety Super- public agency% elevation as approved by the Public intendant. may Ripon request permit. 4. Air,,- work none in order to pro vTorks: Department.. slopes, steeper than two 0 hart.-.. act. tl€ public health, safety and +c} Final Grayling Certificate rontal to one sit vertical- not to welfare in the event of emergency 1. Upon completion of the grad- exceed one it, horizontal to one {'1t or disaster. hrrxg and before final approval is vertical, provided the owner shall "r. Refer to paragraph. t21 of this: :givers, the engineers shall give Writ- furnish a written report by a Soil. :rection and Section Lill, "°Stockpil- ten certification that all provisions Engineer certify=ing that be has in ing,"" for dispersal of excavated ma- Of thisordinance::have been complied vestegated the site rand that the pro- teria:t. with and that all worli authorized hosed deviation will not: endanger. SECTION 1,06 by the grading or paving permit has any property or create a hazard., STOCKPILING been completed, rci The Building and Safety, Supers .,A, grading perinit shall be required:: 2. All:engineering reports shall be intendent may require that the slope.;: `car any offsite stockpiling and: any;:. :submitted to the Building and Safety be flatter than two 0 horizontal to aar°cel of ground used for stockpil- Department prior to final approval, One 111 vertical,"if it is determined ing whore, Over fifty, f$()= cubic v^urds.:. Such reports shall include c'rtiflea-: ..under particular conditions such, flat:-.:. is-cts~.pnd iuof ;;hall be subject to Ser.:-.. turn that the grading, drainage, and -ter surface is necessary, for stabilitc=. 'ion 1,07 Bond Requirement. Stock- paving have been completed accord_ and safety, piling will be permitted on aans5 lot mg to the ordinances of the City` td'E in areas where fill is to ,be or parcol of ground approved by the: .:and the approved plansand s cci- over one t,Ir foot in depth, a. of Building and Safety Superintendent. fications:" Engineer',, report: shall be required. Offsits, stockpiling; shall he limited SECTION L(f) The Soil Engineer shall certify that: to as height of four +4c'feet and shall SAF7:TY PRECAUTIONS the existing soil has been reworked lir limited to a period (if one year; if wit any stage of work: authorized .and all deleterious material removed at whieh time :the fills shall he re- by a valid p€ri,as`t. the Building and 'and has been compacted as required:. movedur compacted and graded to Safety:Department determines by, m-.. by this ordinance, and, that the sub- conform to the requirements, of this spee•tion- that there is an existing soil will :receive all loads to be irn-.. ordinaa:nce, and any other applicable hazard to any....property or public. rposed upon it with adequate sta-- law or code of the City of Redlands. ivAy,, the: Building and 'Safety De- binty against failure, In arenas where It :halt be the responsibility of the partmenit may require that reason- fill exceeds one alt fool; in deldb Owner or permittee to acquire a able safety prewuitions be taken nn the wilding and .Safety Superintend- Soil Engineer's report On said filled nieduncly to .alleviate the existing out may allow the building testing arca and submit the report to:. the. bazar& In the event that the City in extend a nainimunc of twleve r:1:2:r Building and Safety Superintendent is required to furnish barriers or inches into natural approved undi;s-- '.: tLiriled Elul unless designed other- .lope, r'iea_wurcd perpendicular to the rf, Where in the Judgment of the w,`is bs-- r Sail Engineer grid approved slope, and ninety, pLr ceeit '9(Y`'iO be- Building and Safe,r%, Sur e}rintendein d:y^ the Building viral Safety Superm-.: ac,w this piaa'ae.: Cast slopes shall be :it. is necessary, building:. :on graded, terident_ kept free; of loose r aferial during sites shall be equipped with ease: ,e� The tie of filled slopetsshall crnstxu i:mfs. If loose rnr..e.rM rn- putters so that JI storm victor fall he located a rms a 'surn of one-half:. mains on fixe slope after toe col:l ing upon tate reof will he collected: the vertical height of the fill:: pieted slope has been attained, the ..and eisothiete3throng}:... drainage frSara ;a:t:' adjcs_izinp; property= Zine bast- loose it'aat.=sial shall either he re pipe's to all approved location. Drain seed not exceed five "s eel_ moved or las coni pact d, to the sanae age Pipe, shall be of adequate size, 4No -lope-shall oc constructed degree specifled-for hall soil depth and gradient to insure the over aairty-dive 3 � feet in height: w Sufficient tinge shall be spent. scare disposal of the shirr waters, zanies tee Building and Safety Super- by the Soil linginetr on the job site: rill dr'nns shall he sealed to prevent o"11(lrnt rs fnr3nisilLd evidence by ae, v,^hen fills are placed to. perrroi the hannrful infiltr�atiozn,. ,v tet rep€ort from ScAl Engineer uses]Engineer tosiert fie to the proper igs i?etaininr; wall. Where reta.lnu. w rd.a'y'9rrg flail such ;tope w bi be compaction ea£ ail £ills^ owinding any i'!g wails use installed at the toe of stable with a .Lfetr: factor of at trenches, and. the adherence to all.. ..tray drape to Protect :a building. Orly lta-t ,nage and five-tenths, req,uirercents of taxi:. ordinance for shall be constructed of reinforced: +* A twelve �lg, inch high berm Which he certifies. c•onerete or other anaa.sonry and ade .ot curb ..hall 'be placed at the top +p+ Allo.fill material sball be, Pia :d, quately de,-igne3 to support all earth of ,if! slopes and Use, ground surface spread.,.. or ainepacted during un Pressures: incEimibg any :surcharge graded at a nnlninuirn of two per favorable weather conditions, When 1.13 cent 2i arras' from Leena or curb. tic work n interrupted by rain, SE.CTdaES RI This store }sll -Se continued until fill oper..tioss shall not be resumed t I3Ia�C> RESTRICTIONS a n3 water draining from the trip of iuntii field tests by the Soil Engl- Buildings dclear oa- Structures toe shall ISS: facto-all approved near indicate that the moisture con_ c Gator ill p the tale or to cif.. loran tic" be put ctaL car fill slopes according 3,zi the: eii asnaa rack^ice cent of thefill is as y`axt^a,*:iotasly�spec;- falFousng^ p : g Ft The top of all slopes betweert .tree 1 Shia wards: adorning lots.snail b, at the property 9 Material far fill shall consist Crac half a ve the vertical height- ine, of n+.atorsa approved by the Soil of dope With a rout mann of five t5a Exception:on: Any portion of abut- Erginecr i"lae ineateriai fitted shall be feet and a required mallhisurn of teff.. ing property that is not a part of free at, all tame^, from":all organic {1{ir feet for any height slope. take Sita sander development material and rocks of gres'cer di-. 2. Front yards and side yards abut- , x All fill slopee, in excel" cif: mansion than eight 0 inches when ting a street: t naYy-Ei.ve =33e foe vertical` aea.l height: within ten J(h :feet depth of finish A minimuan of:`fifteen 051 feet for ssi sl have concrete water-carrying grade.: any slope where the „rade extends, Terraces it a Inn it ing of twesat,y-- SrECTION 1.12: fourteen per Cent Thldfy, five r25i feet vertical intervals, with GRADING AND DRAINAGE ,,",. Rear yards.. such terraces draining into a con- crete-paved goiter <r pipe adequate sal The grading shall be designed 20a feet I for any height ry convey the,*wrate 7rnMy tai aur:ap- to divert wiiater :away from buildings: slope, except tha..t. a: -proved distiosal area, Drainage ter and slopes. prevent soil saturation Portion of the building not to gut_ races are to be a rninfiGama of five detrinaenntal to the structures and; coed thirty X301 feet in width Mast t5A feet wide. tike use of the lot or parcel of Project to within ten rIol.:feet of the ,ja Tie natural ground surface. ground,.provide for disposal of ex-- toe or tarp of out and fill slopes.. ,hall be prepared to receive fill by rest water front the lot or parcel of if a level r . or 2%, grader open resuoviazg all vegetation, nonconipl;y'- ground, anti provide grades for ;eon_ space halving a minimnnn tdinaension- ing fill, tori soil and: by removal: vesnient: access tax buildhols. rf twenty-five (231 feet and a mini- 'ad ctinapaction of arab' soil not con- .h Buildings shalt be protected by taunt area of two thousand (20 tor-loinzg to tile. stability required to a ininbl nnn slope of two per Cent square feet is provided, Said open support the proposed :loading', "The=. 2`.'r the top of such slope shall be. space shall be located to the rear r,satimurn ,iloxvaable in`aP,ave d loading.. a minhauri of six offs Snches belon, of the front setback line and be ad- shall -ase delinesated in the Soil En the topof the foundation or floor jacent to the neon buildiil:c_;. ^in€.eer's report. lab, said slopeshall extend a nurn-: SECTION 1.14.' -asi When the shme of the existing ar ar disc ince of these .'a feet naeasw. EASEMENTS round to receive till ;s:grealer twic;n ured horizontally from the exterior When it is determined to be nests- five +5, horizontal to one .1s semi-. face of the foundation and t.errni-: s"ary by the Building a.:nd Ssrfergw.. cat the existing clop5e ,halt: be. nate .a'a a draireagi- swaale where sae_ .Superintendent, the City shall re- he_.nt'hod. Five V.i� £ret of the Iaever chaired its protect tine property or quire the c€nvilvatine of necessary belich shall be provielid with ap-: adjacent: properties, casements for drainageway5 and: novel drainage. Ali gauchos shall: ,ea All areas of the £tit, or parcel slopes across and upon parcels of be approved las° the .Soil Engineer of ground shady be developed soas land 'where the continuous function- and ',",ai'din,g and .safety .rsulxnrin- to mov'eL eontrol of starlit and sur- ing of d..rainaagewav`s or the perirn fondant prior to the placing of:fill. fare: -wnt4t-s from damaging the face neat statyxlizationof slopesis deer ee$. +1s All fill sbar.11 be compacted at:: of any"excavation or fill.. All cdrain-. essential to the protection and use or near oroixi n7 noasture conte=nt to aglo provisions shall be approved by of ally other lwaresol or parcels.., a ninnn um dry density of ninety per the Building and ,Safety Depart.nent SECTION 1.15 cent +.d36 r.a of the maxinrium dry den. find sha-sl be of such design as to T'I-AN`S'.I.NG. MAI14w2'Tlwi'ANCE ANIS tnd norder nder the supervision carry s'tornt and surface water to PROTECTIVE DEVICES oy- ri f a Soil Engineer. The fill material tyle nearest practical street, alley, bi, The owner of any property on.: �thall be placed in layers which, sterol drain, natural water course which car excavation or fill has been: c-ccn comported, shaill',. not emceed: or approved drainage, devices as tap- made Purstlant to the provisions of:. sir 6; inches, Each layer shall be proved by the ;Department of Put)- this ordinance, or any other per- pa.ead evenly and shall be thorough-. EcVrorlc;-., son or agent bi control of:such prop_. ly mine=d during; .the ;spreading to: rdl Whenever:: the Building and ',arty, shall maintain all slopes, re-.. insuro uniformity of material in each Safety Superi'..ntendent: determines t:ainiap walls, cribbing:,: drainage,. layer..:unlessan alternate methodthat it: is necessary to: protect ad- structures and other necessar;, prem:.. s designated by flee Soil Engineer' incent properties. he may requiretect.ive devices for his and the ad._.. iii the prebiniriarw soil ;.report which: gran cage.swales to be installed there.- joining property, will achieve the: required encu rce5:rills,. for Such drainage swanks shall have 'b,= All, cut and fill surfaces ex - The inti nu isture :contentof the filled a rophinuen rbion of one ger cent. reeding a vertical height of five foal mator it incl. the; method of <com- or if determined adequate by fe*et,shall be planted and mryisntained. ,:raj-tion: shall be as required by the the Building and Safety Superintend- with a suitable ground cor=er to pro- Soil Engineer and approved by..the.: ent, a slip, of fivrsa-tentlot a.5! of one teet the :slopes again=st erosion. Said Building ,end Safety Supeyrint.ez dant, per rent +]r1 anay bepermitted landscaping to be provided prior to "lW Field deris,ity tests chat:l Ila :and shall terminate into an approved :obtaining final inspectionapproval, nolde as deterniiitied by the Soil drainage device, A slope of five- SECTION' 1.16 I ,neer. but in no mace shall tests tcntbs i.aa of one per rent (le", shalt RESIDENTIAL PARKING, be notde at a greater vertical tae- not be p rroUted unless a deterrent- 1`rRTVC'vVAYS AND WALKS waervalthan two r2r feet. and a mini-.. ration by 'a oU Engineer i:; submit '±.N There shalt be prily=':stied snood. ^•,hart of one test shall be made for ted to the Building and Safely Sillier_ of each garage, a parking .space for ch five hundred �500' calcic yards bilencent certifying that such lesser safe outside parlthi& The parking of rill 'via additional layers of fill slope is adegnato, shave shall extend a sninhouan of „hall be spread until the density reg Where it is de9ernbrred to be twenty 1201 feet out from the fa§tee tfnts indicate that the specified dein- necessary to install catch basins and of the garage slid shall be at least city has been obtained.. splash aprons to protect cut or :fill the width of the garage opening with mt Fill slopes shall be rolled slur slopes, there shall be adequate catch ar i.niptinnull of 'ten (104 feet, The ing construction of the tilt with the basins and splash aprons on each lot. Ytliniinurn crown, sw alo or Bross-=lope cornpacticu, equipment being used:: The maximurn..distancev 'between for the parking space shall be rine for One: fill pl;aceknent. Lines and :catch basins shrill be one hundred per cent tl-,ti gradient find'...the maxi- grime a i-grime shall be maintained oilthe il(lq', feet. Surface waters collented ilium gradient shall be five per centcomported slopes. Compaction cif..the: :shall In, conducted safety= to ,an ap- ('+'Seal,. The longitudinal slope gradient ,lopes. ,ball be eighty^-three per centproved disposal area. Catch basins of the parking space shall be a splash aprons one and h s oes' shall bre concrete 'risinununi. of .:per cent an d1 eg d;. 'l'rE tell :a depth of table rpt iinnc�. xr ole, tine rare of the completed construction or equal. a ninsifi urn of five per cant 5lr-,,i. -,:- When.'a garage floor is, less than... :cord:nee +,irith.. the manufacturer',, APPROVAL OF COMPLIANCE.. three and one-half feet:.+3,5above recommendations, The Building and Safety Superin-. the tops of curb, the twenty a204 foot.- 4. A. :structural pavement section ferment will review the reports, and:. parking space rnay be oinitted.. :designed: by a Soil Engineer and lap- 'open evidence that :all requirements 'bl Driveways shall -extend front proved by the Building and safety of this ordinance have been satin. the property lint: to the carport or Department may be deal in lieu: of factority compiled with, final ap-- yarage.The _adniniuua width of drive- the above paving requirements, pro al shall be given. o days: shall he teas + .lir feet:: All. 9. Drainage: The paved Surface SEC'f'1C)It; 1,22,. driveways shall have a turning shall be designed so as to dispose CONDITIONS <„dins'adequate. for safe ingress and of all Surface waters. Drainage shall: In granting any permit:tinder this. ogre t,. The seemxur,utnx gradient shall be to rice curb. gutter, alley” or pub- ordinance the Building :and Safety=: be notmore than twenty per :cent: he drainage facility and:away, from =Superintendent may attach such ad All vertical transitions shall- adjoznritg properties and buildings. ditlonal requirements and conditions be made ,sith:. not less bran: four Such drainage shall not be allowed as may:.be deemed reasonably neves- foot W) parabolic vertical curve;. :to cross the surface of a public :scary to .protect.. public or private: .,izen the driveway gradient exceeds: ;sdewalk area. Catch basins may..be:: property or to prevent the operation fourteen per can, tl,41,t; the vertical installed and the surface wafters from being hazardous to life and transitions Shall be in eight foot piped under the Sidewalk through properly or in a manner likely to il°o parcbolic vertical curve. The the curb to the street ?utter or create ai nuisance. c' v"n, Swale,: or cross slope shall :drainage channel, as approved. by SECTION 1.23 '..:. rohe o. minixemn gradient of one:. the Public ark" Depaartuient. Catch NON-LIABILITY per cent ryes€;:the maxuruan gradi- basins shalt be concrete construction No provision of this ordinance shall. ent shall be not more than five per or egmil, be construed as imposing upon the cent ;at'�r.. SECTION L13. City of Redlandsany liability or rc-:. ,ci Entrance. Walks and steps from PROTECTION AND SAFETY' sponsibihty. for damages to any per- the public way shall be a mirumuan tak No per-ora:. firm.,. or corpora- son who suffers injury, nor shall of three ¢3r feet in width and have tion shall do or cause to be done, the City of Redlands or any em- a niaximuanx longitudinal gradient of any gr'athug ;work on lands suf_ ploK ee thereof be held as assuming ten per cent lI0'.E; the cross-slope ficientl:v close to the property line any such liability= or responsibility gradient shall be a minimum of one to endanger any adjoining public: by reason of inspection authorized. per cent rlsl r and a aaasinnain of street, sidewalk, alley, or other puts- hereunder, nor shall the City of Red five per cent FSs ',J, Where the slope..: :lic or private:.. properties without :lands or any employee thereof be is greater than fourteen per cent. Supporting and protecting such prop- held as assuming any liability or re- '!4''i rs.. step, shall be used to pro- erties trona damage which might re sponsibfflity for property damage. vide safe ascent and descent; such.. sult from such grading work, While from any cause:whatsoever: steps shall not be less in width than :grading.work iso.being accomplished;: SECTION 1.24. the walk. The rise andrun of the .the sailshall be kept at a moisture PENALTY ;steps shall be ulaiforrs the maxi content:: adequate to prevent an ex-: murna rise of tread shall be not more A person. violating any provisions; which amount a dust. Any damage than.eight :3s :inches and rite naita,i- which recurs during the t;ourse.. of of this ordinance shad be guilty of: mum run for the tread shall be not construction will be corrected with nuederneanor. and upon conviction less than nine t9i inches. in forty-eight (48) hours by the per- thereof shall be punished by a fine ed, Cmwt.c.:i"ion. Construction of mittee or the owner. of not more than five hundred dol- driveways shall conform to the foi the It shall be the responsibility= lars ($500) or by iraprisonanent for loss=ing: of the owner or permittee to 4ocate a term not. exceeding six (&) months, 1 A driveway design is to be sub all utility lines,stores slivers, irrsga or by both such fine and itnprison rnitted: for all driveways, tion lines, and any other service trent. Such person shall be deemed. . Subgrade .shall be compacted, utility located on the parcel of guilty of a separate offense for each he well-drained, sterilized with an ground. The owner or permittee A all and every day during any portion: approved weed kilter, applied in ac- make necessary arrangements to of which any violation of this ordi- cordance with the manufacturer's have any such utility relocated if nance is committed, continued or rectsntmendations. :and uniformly :said utility should pass beneath :the permitted. graded parallel to the contour of the structure or within the angle of re- SECTION 2 finish::pavement.. .pose of the foundation. The angle If any:section; subsection, clause;: 3. A minim rna of three 0 inches of repose shall be a 4.51.:line drawn phrase,..or portion of this ordinance of compacted base shalt be required from the outside edge at the base is for any reason held to be in- over any expi n uve soil. Said; base of the structure's foundation. The valid or unconstitutional by the de- :hall be of crushed Slavic, gravel', or Building and Safety Superintendent vision of any court of competent other durable road material= shall be notified of the location of jurisdiction, such decision shall ixot 4. Concrete pavement shall hae:e.. all said utilities; suchnotificationafi'ect the validy: of the remaining.: .a a irii stir tl ickness if three and strati lasclude a: map showing the portions of this ordinance. five-eighths +310 inches and as mini location, size. depth and type- of SECTION 3 mum design strength of 2,t1b0 PSI, utility prior to commencement of That Ordinances 1235, 1262 and Expansion,joints shall be provided at. worts:. :The Building an d Safety 1283 and all other ordinances or all pulth v,ams. curbs, garage slabs:,. Superintendent shall be: notified of .:parts of:ordinances in conflict here carport; slabs.; :and building walls, any proposed chlarigee of:utilities;. with are::.hereby.:repealed. : Paving shalt he finished true to the SECTION 1.19 SECTION 4 cross lection and grade. RESPONSIBILITY OF THE This Ordinance shall be In force 5. Bituminous paavernent shall be PERMITTEE and effect as provided by law. not less than ripa one and one-half tl3r`zr Grading permits shall be presumed SECTIO 5 ouches compacted thickness ors and shall to incorporate the provisions that The City Clerk shall certify to the be finished tate to the cross section and grade, the applicant, his agent,: employees. passage of this Ordinance: and Shall SECTION 1.17 or contractors shall carry out the cause the -area to be published once NON-REa113ENTIAL. PARKIriG•. Proposed work in accordance with, :in the Redlands: Daily Facts, a news- At', non-residential off-street park- the approved plans and with all re- paper hereby designated for that: ing areas and vehicle sales areas, as quireanents of this ordinance and any purpose. defined in Ordinance 1254 of the other lades or regulations applicable s,l WALDO F. BURRt"}LlGHS. City of llediands, shall be graved:. thereto,: The approved plains shall Mayor of the Cate- of Design plans shall be submitted for not be changed or modified without: Redlands, all proposed paved areas; the approval of the Availing rind Attest.;: w Construction, Safety Superintendent; such changers I'ECgGY A. IvI{}SELEY„ 1. Subgrade: The subgrade under shall be incorporated on the plans City Clerk all prated areas shall be compacted on file in the office of the Building o ninety per cent t90'=rr of maxi and Safety Department of the City Approved for Forzxx: stam density- for a depth of twelve of Redlands, Approval of plans shall sl EDWARD T'; TAYLOR, 12r mchcs.. not relieve the :permittee from the City= Attorney, 2, Base; Sit roe inches of Glass.. :responsibility of voinplyi g with the 1, Peggy A. Moseley, City Clerk 'live t2r aggregate base; as defined provisions and intent ofthis ordi-:. .City of Redlands, hereby certify that. by the State of California Standard ounce, the foregoing ordinance was duly .,pr eificationa. latest edition, shall be SECTION 1.20 duly adopted by the City:Council at:. required under all paved. areas. C)NV EP, RESPONSIBILITY a regular nieeting thereof held on 3, paving shall conform to the fol- Compliance with the requirements the 17th day of May, Illtsfi, by the,.. lowing:: and conditions of this ordinance following vote, a. Concrete; Three and fine--eighths shall not be construed to relieve the AYES: Councilmen Martinez, Hart- .isz,i inches of 2,000 PSI designownerof any legal duties. obliga- ;testi, Cummings, Mayor Burroughs, strength Portland convent concrete, tions, or liabilities incident to the or ownership of the property while the NOES: None, b. Asphalt:Two ilh inrluss of dense work authorized by this permit is ABSENT: Councilman DeMirjy'n, graded: asphalt:. concrete pavement., being performed or after the com. VE GY A. MOS LEY,.. with subgr:ade sterilized with an cap- pletion thereof. proved weed killer applied in ae SECTION 1.21; City Clerk; —4—