HomeMy WebLinkAboutOrdinances_1444_CCv0001.pdf ORDINANCE NO. 1.444
AN ORDINANCE AMENDING THE R.E'DLANDS ORDINANCE C ODE FOR THE PURPOSE
OF UPDATING AND ADOPTING THE LATEST EDITION CSE THE UNIFORM RVJm-
INC CODE AS PREPARED BY THE INTERNATIONAL ASSOCIATION OF PLUMBING
AND MECHANICALOFFICIALS AND RESCINDING ORDINANCE NO. 1383
THE CITY COUNCIL OF THE CITY CE REDLANDS DOES ORDAIN A8 FOL-
LOWS:
OL-L WS ;
SECTION ONE: That the Redlands Ordinance Code be amended
and updated by deleting present Article 841 of Chapter 84 of
Division 8, Building, and replacing with Article 841 as follows :
BUILDING UNIFORM CCDM 84100
ARTICLE 841.
Uniform orm lu bing Cade
84100. That certain document on file in the
office of the City Clerk of the City of Redlands which is
Marked and designated as "Uniform Plumbing Cade, 1970 Edition, "
and each and ;all of the regulations, provisions, conditions,
terms and appendices of said Uniform Plumbing Code are hereby
referred to, adopted and made a part, of this section. That
there are three copies of the above referred to document and
Code now on file in the office of the City Clerk. (1444)
The parts, chapters, sections and appen-
dices are hereby amended by the following deletions, additions
or changes in wording.
84101 .= PART ONE - ADMINISTRATION
Sec. 1s1 - ADMINISTRATIVE AUTHORITY AND
ASSISTANTS. In the Uniform Plumbing Code referred to, insert
in the blank space provided, the words "Director of Building
and Safety",
Sec. 1 . - ASSISTANTS . Insert in the
blank space provided, the words, "Senior Electrical and Plumb-
ing Advisor"
Seg.:... 1 . 3 - DEPARTMENT HAVING XUR DIC-
'ICN.: Insert in the blank space provided, the wards, "Building`
and Safety" .
Sec. 1.4 - DUTIES OF THE ADMINISTRATIVE
AUTHORITY. Delete paragraphs ) ( and 10)
Sec. 1. 7 - VIOLATIONS AND PENALTIES.
Insert in the first blank space provided., the words "Fire Hun-
dred
un =dred Dollars ($500.00) " , in the aecond space the woad "County"
and an the third space the ward "six" .
Sec. 1 . 10 - TO WHOM PERMITS A.S. BE IS-
SUED. Paragraph a) shall read as follows:
" (a) No permit shall be issued to any
person, firm or corporation to do, or cause to be done, any
plumbing, or work on a Plumbing System, Sewer, Sewage Disposal,
Drain or work regulated by this Cade except to a person, farm
r corporation holding, a valid unexpired and anrev k;ed license
as issued by the State cif California and a receipt for payment
5/18/71
oomi
W
BUILDING UNIFORM CODE 84101 Cont.
" of all Revenue Fees as required by Chapters I. and 22 of
Redlands Ordinance Code except when and otherwise hereinafter
provided in this Section. "
Sec. 1. 112 - COST OF PERMIT. The second
paragraph shall, read as follows :
"Such applicant shall pay to the City
Treasurer' s Office, for each permit issued, at the time of is-
suance, a fee in accordance with the following schedule, and
at the rate provided for each classification shown thereon. "
Sec. 1.15 - BOARD OF APPEAL shall be
added to read as follows ;
"The Board of Appeal and the procedures
concerning its operation as stated in Section 84002 of Article
840 of the Redlands Ordinance Code shall also apply to all
appeals resulting from the administration of this ode. "
Sec. 1.16 - ANNUAL PERMITS shall be
added to read as follows:
"Where any person, firm or corporation
proposes to install, alter, or repair any plumbing, drainage
system, septic tanks, seepage pits, or leaching lines, and for
which work said person, firm or corporation is able to and does
in fact, furnish inspection service which meets the require-
ments of the Administrative Authority and the Ordinances and
adopted Codes of the City of Redlands, and whose operations are
(1) subject to the jurisdiction of the California Division of
Industrial Safety and (2) conducted under the continuous super-
vision of an inspector approved by the Redlands Director of
Building and Safety, suc'h person, firm or corporation shall be
required only to obtain an Annual Permit.
"TfLe fee for such Annual Permit shall be
as follows, based on the number of plumbers, pipe fitters or
maintenance men doing plumbing work:
1 to 10 . . . . . . . . . . $100.00
11 but not more than 75. . . . 200.00
"In any instance where the inspection
service rendered by any person, firor corporation a; provided
in this section is not in accordance with the rules and regula-
tions of the Director of Building and Safety, and with the re-
quirements of the Unifor-mr Ptum ibing Code, the Director of Build-
ing and Safety is hereby authorized to cancel. said Annual Permit,
5/18/71
BUILDING UNIFORM CODE 84101 Cont.
"by giving written notice, and said person., firm or corporation
shall then be required to pay the reqular° permit fee and t
submit plans and specifications before work can be allowed to
proceed. :tans and specifications for all new work to be dune
by contract will stili be required to be submitted for approval
and permit fees paid prior to initiation n f the work, A quar-
terly inspection will. be made by the Director of Building and:
Safety to review compliance with this Ordinance. "
"
84102. PARS` IO - QUALIFICATIONS OF L' EE,
This part and all sections applying thereto are deleted,
84103. CHAPTER 2. QUALITYWEIGHT'S OF
MATERIALS, ALTERNATE MATERIALS, ALTERNATE METHODS OF CONSTRUC-
TION.
ON TRUC—°; ION... An additional Section shall be added reading as follows:_
"Sec. 211. T.T E OF PLASTIC PIPE AND
FITTINGS .
" Plastic pipe and fittings shall
be limited to residential type construction of not over two
stories in height and for DWV application only t shall be
installed within the limitations of this Section, Standard IS
5-66 (UPC) , and etherapplicable -instructions issued by the
Administrative Authority,
" (b) Mastic pipe less than Schedule 8
shall not be threaded
", (c) Only "approved metallic traps may
e used with connections made by means of appro,,:red inale threaded
trap adaptors. Metallic traps with plastic fused adaptors mai
be used.
" (d) Shower drains shall be connected to
their traps by metallic piping.
" (e) Two-inch nch °No-h b' or similar type
compression couplings may be used as transition fittings and
n appropriately sized compression couplin used to connect the
hawse drain to the house sewer.
"° f Closet flanges shall be of the type
incorporating rat ng a plastic coated metal ring with a center section
of plastic that may be, solve welded to the bend or stub. All
closet rings must- be securely fastened, to the building s raac
t;ure or concrete floor, in zepencient of the plumbing system. All
screws or fasteners shall be of brass or corrosive resistant:
(stainless) steel.
5/18/71
BUILDING UNIFORM DE 84103 Cont.
" (g) Plastic pipe and fittings shall: not
be used where they would pierce fire separation walls, floors
r ceilings such as the garageside of a dwelling wall or ceil.-
ing for an attached private garage..
" (h) No plastic waste piping except
cleanouts shall be exposed on the exterior of a building where
they may be exposed to direct sunlight.
" M Plastic pipe and fittings placed in
the ground shall be bedded on a minimum of 4" of sand, sandy
loam or similar material containing no clods, racks, etc. and
backfilled with a minimum of 12" of the same materiel. The
trench shall. be backfilled' immediately or the pipe shaded with
small quantity of backfill until: backfilled.
" (j ) Solvent cement shall be used only
from the original container and will. not be thinned.
" (k) A slip-fitting shall be installed
ed
in all vertical reins of two-story structures that are not
relieved by off-sets and where stress can be created by shrink-
age of wood structural members ; "
84104 CHAPTER 3 . INSTALLATION REQUIREMENTS.
Sec. 303 - SEWER REQUIREMENTS . An addi-
tional, paragraph shall, be added as follows:
" (d) A11- soil and waste piping from a
structure shall. be joined together either under or outside o
the structure to form one building drain system from a point
two or more .feet outside the building or structure. The sail
and waste piping shall be cast iron or ABS to the paint where
the lines are joined or to the required two-way cleanout if it
is beyond the point of joining.
Sec. 323 - Deleted in its entirety.
84105� CHAPTER 4. DRAINAGE SYSTEMS .
Sec. 401 - MATERIJUS. An additional
paragraph shall be added reading as follows
" (b) 3 . Fittings for ferrous screwed:
pipe, and ferrous screwed pipe are prohibited for use in a drain-
age system. "
518 '` 1,
BUILDING UNIFORM CODE 84106
84106 CHAPTER 5. VENTS AND VENTING.
Sec. 503 - MATERIALS, The last word,
"ground", shall be deleted from paragraphs a) and b) and the
or "finish floor elevation" added,
84107. CHAPTER 8. JOINTS AND CONNECTIONS .
Seam 802 - 'HYPES OF JOINTS . This Sects,
tion shall be amended by deletion of paragraph f)
Sec. 803 - USE OF JOINTS . This Section
shall be amended by changing paragraph (a) to read asfollows;
" (a) Clay Sewer Pipe -- Joints in vitri-
fied clay pipe or between such pipe and metal pipe :shall be
made as provided in sub-section (g) or (l) of Section 802. "
84168 CHAPTER ltd WATER DISTRIBUTION.
Sec. 1007 WATER PRESSURE, PRESSURE
REGULATORS AND PRESSURE RELIEF VA:-F,.,V shall be changed b
changing the wording of sub-paragraph b) Excessive Water
Pressure. All references;, t "one hundred 100) pounds per
square inch's shall be (:,,hanged tc "eigh y-fi'e (85) pounds h=er
square inch"
Sec. 1008 - INSTALLATION, INSPECTION AND
TESTING shall be amended by deleting paragraph c) 1) and b
adding a sentence to paragraph (e) TESTING, reading; as follows:
"Full pressure of water from the street
main or an air pressure of not less than fifty 50) pounds ds pe.r
square inch shall be maintained on the system at: all time
during construction ction operations ,
34.1.1 CHAPTER E ll. BUILDING SEWERS ANO PRIVATE
SEWAGEDISPOSAL SYSTEMS .
Sec. 1101 - SEWERS REQUIRED. Paragraph
d) shall:. be amended by changing the wording to read as follows:
" (d) A public sewer shall_ be c n -i Bred
as riot being available whenSuch public serer is more than one
hundred 106) feet: tram the nearest point: or the property t
such public serer. In addition, if other dilEficulties , such
as insufficient elevation differential to permit gravity 3.
to the sewer, are resent the Administrative Authority ity shall
5/'18 `71
3 k
ti4�..;ais7
BUILDING UNIFORM ODE 84109 Cont.
"investigate the situation and make a determination as to wheth-
er unreasonable difficulties exist': to making connection to the
public sewer. His decision may be appealed through the Appeal:
Board as outlined in Section, 1. 1. . t1
Sec. 1103 -- BUILDING SEWER MATERIALS ,
Paragraph a shall be changed by adding an additional sentence
reading as follows:
"Bitumini, ed fiber sewerpipe or fittings
shall not be considered an acceptable material in any building
drain or building sewer, "
Sec. 1107 - CLEANOUTS . Paragraph (a
shall be changed by adding two additional sentences reading a
' lbws
"The cleanout located at the junction of
the building drain and the building sewer" shall. be ,a two-way
directional fitting. The cleanout shall be extended to finish
grade. "
Sec. 1.111 PR,rVATE SEWAGE DISPOSAL
(GENERAL) . An additional sub-paragraph shall be added as fol-
lows:
ol°lCawsffi
" (h) All seepage pits and septic tanks
shall be located in the front yard area setbacks as defined in
Redlands Zoning Ordinance 1,000, if this is not possible, the
Administrative Authority shall rake a determination_ of an alter-
nate location .
See, 111 - DISPOSAL FIELDS . An addition-
al ,sub-paragraph i) shall be adders reading as follows
" (i) Disposal fields shall be used only
when a determination has been made by the Administrative Author-
ity that no other procedure is feasible. "
8411.0. CHAPTER 13. WATER. HEATERS VENTS .
Sec. 1311 ;ACCESS AND WORKING SPACE.
This Section shall be amended by substituting the following:
"Access and working space shall be pro-
vided
ided in accordance with the .r quiremon.t of the chapter on
C omf"o. t Heating Systems of the Uni.forri Mechanical Code as adop-
ted
ted by article 843 of the Redlands ordinance Code. "
5/18/71
zAir
sa
BUILDING UNIFORM CODE 84119 Cont.
Sec. 131 - PRESSURE RELIEF VALVES
This Section shall be amended by the addition of thefollowing::
"Relief gents will be carried t floor
sink or to the outside of all habitable portions of structures.
The :rent shall terminate six inches above the sink overflow
rim or ground surface. The end of the crena shall not be a
threaded pipe or fitting. "
8411:1 . APPENDIX shall be amended 'by deletion
of paragraph G9. (1444)'
/18/7
SECTION TWO: Each provision sof this Ordinance shall be separate
and severable and in the event any specific provision: is declared void
or invalid, no 'other section, otherwise legal and valid, shall b
affected hereby.
SECTION THREE: Ordinance No. 1383 and all ether ordinances or
parts of ordinances in conflict herewith are hereby repealed,
SECTION ECS This Ordinance shall:- be in force and take effect as
provided by law.
SECTION FI The City Clerk shall certify to the passage of this
Ordinance and shall cause the same to be published once in the Redlands
Daly Facts, a newspaper of general circulation printed and published
in the Cityof Redlands.
ATTEST: JyvaAo-ft.he City of R.edi n s
Cier
APPROVEFORFORM;
Edward a Ta for
City Attorney
Peggy Aa Moseley, City Clerk of the City of Redlands, hereby certify
that the foregoing ordinance was duly adopted by the City Council: at a
regular meeting thereof on the 18th day of May, 1.971: by the following
vote
AYES : Councilmen De irjyr , Knudsen, Miller, Sewall., Mayor Cummings
`CES None
ABSENT:` done
City rk
Ordinance ',N . 1444
'age nine